About double-layer glass reactor reference price, parameters, instructions for use and maintenance

Double glass reactor description
The glass vacuum reactor is a double-layer glass design, a double-layer glass reactor, and the inner layer is placed in a reaction solvent to perform a stirring reaction, and the interlayer can be heated by a different cold or heat source (refrigerant, hot water or hot oil) or Cool the reaction. Under the constant temperature condition, in the closed glass reactor, the stirring reaction can be carried out under normal pressure or negative pressure according to the use requirements, and the reflux and distillation of the reaction solution can be performed. It is a modern fine chemical factory, biopharmaceutical and The ideal pilot and production equipment for the synthesis of new materials.
Double glass reactor features
● Frequency control, AC induction motor. Constant speed, no brush, no spark, safe and stable, can work continuously.
●The complete glass instrument is made of GG17 borosilicate glass and has good chemical and physical properties.
●The glass interlayer interface is connected to the hot oil through the circulation, which can be used for heating reaction, and the low temperature reaction can be carried out by using the frozen liquid.
● It can react at room temperature, and it can quickly take away the reflected heat when it is connected to tap water.
●The lower discharge port has a flange mouth and a PTFE valve. There is no dead angle in the container, which can be disassembled to facilitate the discharge of solid materials.
● Five-port reactor cover, the extra-large port design is easy to clean, and the standard port socket can be assembled and reflowed, and the distillation synthesis device.

Double glass reactor BL-1L parameters
model
Volume
(L)
Motor Power
(W)
Rotating speed
Mixing torque
Inner and outer diameter
(mm)
Glass kettle lid related opening
price
(yuan)
middle
left
right
Rear
Just before
BL-5L
5
90
50-800
5000g.cm
200*230
50#
29#
twenty four#
twenty four#
19#
12800
BL-3L
3
90
5000g.cm
200*230
50#
29#
twenty four#
----
19#
7800
BL-2L
2
90
5000g.cm
150*180
50#
29#
twenty four#
----
14#
6800
BL-1L
1
40
2400.g.cm
150*180
50#
29#
twenty four#
----
14#
6200
★ Optional explosion-proof motor. (Explosion-proof motors have explosion-proof certification)
★ Other "well" word fixing bracket is optional
Double glass reactor BL-10L parameters
model
Kettle capacity (L)
Number of bottles
Cauldron diameter (mm)
Motor power (W)
Vacuum degree
(Mpa)
Speed ​​(rpm)
Torque (Ncm)
power supply
(V)
price
(yuan)
BL-50L
50
5
265
180
0.096
50-600
300
220
38800
BL-30L
30
120
210
32800
BL-20L
20
120
162
26800
BL-10L
10
120
162
19800
★ Optional explosion-proof motor. (Explosion-proof motors have explosion-proof certification)
Single layer glass reactor DGN - 2L parameters
◆Outer size (cm): 50×36×85
â—†Reactor volume: 2L (upper discharge)
◆Hettle lid: ¢150mm three-port glass lid
â—†Motor power: 40W
◆Speed ​​control: electronic speed control
◆Bath pot: 1.5kw [water bath 0~100±1(°C)/oil bath 0~180±1(°C)]
◆Stirring rod: ¢6-8mm curved piece
◆Speed ​​(rpm): 50~1200
â—†Rot distance (gcm): 2400
Single layer glass reactor DGN-5L parameters
◆Outer size (cm): 50×65×156
â—†Reactor volume: 5L (upper discharge)
◆Hettle lid: ¢150mm three-port glass lid
â—†Motor power: 90W
◆Speed ​​control: electronic speed control
◆Bath pot: 2kw [water bath 0 ~ 100 ± 1 (°C) / oil bath 0 ~ 180 ± 1 (°C)]
◆Stirring rod: ¢6-8mm curved piece
◆Speed ​​(rpm): 50~1200
â—†Torque (gcm): 4800
Double glass reactor step
1. After opening the package, check whether the main accessories of the machine are complete according to the packing list.
2. Assemble the frame in accordance with the drawings as shown in the figure.
3. Install the electrical box on the top of the right rear pole and tighten the screws and insert the seven-pin plug. Install the vacuum gauge on the left rear end and tighten the screws.
4. According to the height of use, fix the round bracket of the kettle to the vertical pole slider, and place the kettle on the bracket. The semi-circular hoop is used to insert the vertical rod into the pole of the kettle, and then tighten the fixing screws after closing. Pay attention to the vertical direction of the reactor body during installation.
5. The stir bar is fixed on the ring clamp of the motor main shaft. The stir bar passes through the middle rotary bearing of the cover, tightens the special connector, and then adjusts the position of the motor, paying attention to the vertical concentricity.
6. The slider on the pole is a stainless steel multi-purpose clamp that adjusts the direction and height in different directions.
7. On the left side of the bottle cap, the 40# standard port plug-in type reflux condenser, the right side 40# is the feeding port connected to the constant pressure funnel, the middle front 24# port is the plug-in thermometer casing mouth, and the hat rear is the 34# standard port. It is a multi-functional spare port, and the bottom is provided with a discharge valve, and the bottom of the kettle body is respectively a circulating fluid inlet and outlet. The lower port is connected to the circulating fluid inlet, and the upper port is connected to the circulating fluid return port.
8. When installing the glass instrument, it must be cleaned, and the interface should be coated with Vaseline to prevent the glass from locking up, and then apply vacuum grease to prevent air leakage.
9. Press the universal wheel wheel fixing device to stir. If the stirring is stable, the debugging is good.
Double-layer glass reactor operation procedure
1. Check that the power supply voltage is consistent with the specifications provided on the machine nameplate.
2. Plug in the power plug, turn on the power switch on the inverter, and use the speed control knob to select the appropriate speed.
3. The flow of material and the power of the motor speed may resonate at a certain point. Please change the speed of the motor to avoid resonance.
4. After the stir bar is installed, it must be rotated by hand. Pay attention to whether the concentricity is good. If the heart is not good, the heavy clamp should be loosened. After the clamp is turned on, turn on the power and adjust gradually from slow to fast.
5, using the stir bar regulator, you can make the stirring leaves up and down 5cm as needed.
6. If the sealing performance of the kettle is found to be degraded, please check the rotary bearing in the agitator sleeve.
7. The glass equipment of the reactor is made of GG.17 low expansion coefficient high temperature resistant borosilicate glass. The user should self-fit glass bottles such as reaction bottles. Please confirm the glass material to ensure safe use.
8. The external layer of the interlayer on the glass kettle can be heated by the hot oil. The coolant can be used for low temperature reaction. If it is heated by steam, it should not exceed 0.5K-1K. (Try not to use pressure steam to heat).
9. When the double-layer glass reactor is tested at low temperature, the discharge valve at the bottom will be frosted. When using the valve, it must be partially thawed to prevent the glass from being broken.
10. If there are particulate objects in the solution during use, it is possible to store the remaining materials on the PTFE piston of the valve. When used again, the airtightness will be affected. Be sure to clean and re-use each time after discharging. .
Double-layer glass reactor maintenance
A. Check the instrument carefully before use. Whether the glass bottle is damaged or not, and whether the interfaces are consistent, pay attention to light handling.
B. Note that this equipment is a fragile product. Please be careful when using it. The damage of fragile products is not covered by our warranty. If the customer needs, we will charge the corresponding cost.
C. The PTFE switch in all places cannot be tightened too much and it is easy to damage the glass. 4. Turn on the power switch first, then let the machine run from slow to fast. When the machine is stopped, stop the machine and turn off the switch.
D. The interfaces should not be tightened too tightly. It should be loosened regularly to avoid the long-term tight lock and cause the connector to die.
E. Every time you use it, you must wipe off all kinds of oil stains, stains and solvents left on the surface of the machine with a soft cloth to keep it clean.
F. Clean the seal ring regularly by removing the seal ring and checking if there is dirt on the shaft. Wipe it with a soft cloth, then apply a little vacuum grease and reinstall it to keep the shaft and seal ring smooth.
G. Loosen the PTFE switches after stopping, and the PTFE piston will be deformed when it is still working for a long time.
H, the electrical part must not enter the water, it is strictly prohibited to get wet.
I. The original authentic accessories must be purchased. Any use of other accessories can cause fatal damage to the machine.
J. When doing any repairs or inspections on the machine, be sure to cut off the power supply and water source.
K. The instrument is returned to the manufacturer for maintenance once after three years of use (recommended).
L. Wipe each interface with a soft cloth (can be replaced with a napkin) and apply a small amount of vacuum grease. (The vacuum grease must be covered after use to prevent the entry of sand.)
Double-layer glass reactor common problem solving method
Now    Elephant
original    because
row    except
Turn on the power switch and the indicator light does not light.
External power supply is not connected or has poor contact
Ask a professional electrician to check the power supply and socket.
Fuse short circuit
Set the power switch to the OFF position and replace the fuse.
The power indicator is on but not rotating.
Rotating shaft rust
Stop using and contact the supplier
Motor, electrical box failure
7-pin plug not connected
Reconnect the seven-pin plug
The vacuum suddenly disappears
There is crack in the glass and the switch is broken.
Check the glass parts and switch the switch
There is a vacuum, but I can’t get it.
The seal is worn and the vacuum switch is connected to leak
Please replace the seal, switch
Sometimes there is no vacuum
There is a loose connector on the steel shaft.
Please remove the dirt check vacuum gauge, vacuum pump
Vacuum hose aging
Please replace the vacuum hose
The main mandrel is loose left and right
Tightening screw
Screw tight
Motor temperature is too high (room temperature plus 40 ° C is normal)
overload
Stop, turn the shaft by hand, whether it is heavy, remove the dirt on the contact part of the sealing ring and the glass shaft, apply vacuum grease
The speed display does not match the actual
The voltage is unstable and has its own error
Contact the supplier
Enclosure charged
The heating pipe has cracks and water
Please check with a professional electrician
For more double-glazed reactors, please visit:

Most products of Fluorine-containing Benzonitrile is a colorless transparent liquid and has a pungent odor. It was widely used in pesticides, pharmaceuticals liquid crystal material manufacturing. High efficiency, low toxicity and residue characteristics. Through extensive research and production practice, we have found some good manufacturing processes of fluoro-containing cyanophenyl products. In addition, we have groundbreaking research on ratio of raw materials, solvent selection, the choice of solvent concentration, related use of catalysts..

Fluorine-Containing Benzonitrile

Containing Benzonitrile,Trifluoro Benzonitrile,4-Amino-3-Trifluoromethoxy,Fluorine-Containing Benzonitrile

Taizhou Volsen Chemical Co., Ltd. , https://www.volsenchem.com